Lead Pipe Map

Middletown Twp., NJ · PWSID NJ1331001

Gateway Nra Sandy Hook lead service lines

45 lead or galvanized lines to replace

Gateway Nra Sandy Hook reported 0 lead and 45 galvanized-requiring-replacement service lines out of 120 in its inventory. That's 38% of all its lines. Another 11 (9.2%) are still listed as unknown material.

Ranks #126 of 240 New Jersey systems with confirmed lead lines, and #2,748 nationally.

38% of Gateway Nra Sandy Hook's service lines are lead or galvanized requiring replacement. That's higher than the New Jersey average (4.5%) and higher than the national average (3.1%).

0Lead
45Galvanized, replace
11Unknown material
64Non-lead

Total service lines reported: 120. Reported all required service line types. Population served: 500; 138 connections.

Lead test results

Gateway Nra Sandy Hook's most recent 90th-percentile lead result (Jan 2026–Jun 2026) was 2.3 ppb, below both the 15 ppb action level and the 10 ppb level that takes effect in 2027. This means 90% of homes sampled were at or below that level; individual homes, especially those with lead lines, can be higher.

1510Jul 2022–Dec 2022: 3.6 ppb2022Jan 2023–Jun 2023: 2.8 ppb2023Jul 2023–Dec 2023: 4.2 ppb2023Jan 2024–Jun 2024: 1.7 ppb2024Jul 2024–Dec 2024: 2.7 ppb2024Jan 2025–Jun 2025: 1.7 ppb2025Jul 2025–Dec 2025: 8.6 ppb2025Jan 2026–Jun 2026: 2.3 ppb2026

Lead and Copper Rule 90th-percentile results reported to EPA, in parts per billion. Dashed lines: 15 ppb action level and the 10 ppb level from November 1, 2027.

Progress since 2025 Q1

Reported lead and galvanized-requiring-replacement lines went from 45 in 2025 Q1 to 45 in 2026 Q3: no change. Lines of unknown material went from 11 to 11, no change.

2025 Q1: 45 lead + galvanized452025 Q12025 Q2: 45 lead + galvanized452025 Q22025 Q3: 45 lead + galvanized452025 Q32025 Q4: 45 lead + galvanized452025 Q42026 Q1: 45 lead + galvanized452026 Q12026 Q2: 45 lead + galvanized452026 Q22026 Q3: 45 lead + galvanized452026 Q3

Quarterly counts reported to EPA. A drop usually means lines were replaced or confirmed non-lead; a rise usually means more lines were identified. Replacement progress rankings.

Lead rule violations

EPA's data lists 9 Lead and Copper Rule violations since 2015, 2 health-based, 1 still open for Gateway Nra Sandy Hook. Health-based violations are treatment failures, such as corrosion control or public education; the rest are missed monitoring or reporting.

BeganViolationStatus
Apr 2026Lead consumer notice not delivered or reportedOpen
Jul 2025Missed water quality parameter monitoringReturned to compliance
Sep 2022Lead consumer notice not delivered or reportedReturned to compliance
Jan 2022Water quality parameters out of range health-basedReturned to compliance
Jul 2021Water quality parameters out of range health-basedReturned to compliance
Jan 2021Missed water quality parameter monitoringReturned to compliance
Jan 2020Missed water quality parameter monitoringReturned to compliance
Dec 2019Lead consumer notice not delivered or reportedReturned to compliance
Jan 2019Missed water quality parameter monitoringReturned to compliance

Source: EPA SDWIS violation records for the Lead and Copper Rule.

Where the water comes from

Gateway Nra Sandy Hook's main water source is groundwater (wells).

Source: EPA SDWIS water system and facility records.

Check your own address

These counts cover the whole system. To see whether your line is lead, use the utility's address-level inventory. Utilities had to prepare one by October 16, 2024 and make it publicly accessible; systems serving more than 50,000 people must post it online.

No map yet? Do the 2-minute scratch and magnet test on the pipe where water enters your home.

Protect your drinking water now

If your line is lead, galvanized or unknown, filter water for drinking, cooking and baby formula. Use a filter certified to NSF/ANSI 53 for lead. Run cold water for a few minutes after it sits for hours, and never use hot tap water for cooking.

How to pick a lead-certified filter · How to test your water for lead

Getting the line replaced

EPA's Lead and Copper Rule Improvements require most systems to replace lead and galvanized-requiring-replacement lines by December 31, 2037. Ask Gateway Nra Sandy Hook whether it replaces the private side for free or with a cost share before you hire anyone. If you want it done sooner, or your utility doesn't cover your side, a licensed plumber can quote it. What replacement costs.

County pages: Lead pipes in Monmouth County

ZIP codes served

ZIP codes whose center falls inside Gateway Nra Sandy Hook's mapped service area (EPA service area boundaries). Neighboring utilities may serve parts of the same ZIP.

07732

Other water systems nearby

SystemLead + galv.Unknown
NJ American Water - Coastal North2,84574,724
Belmar Water Dept375215
Red Bank Water Dept438445
Freehold Borough Water D2050
Matawan Borough Water de144454
Avon by the Sea Water de2670
Farmingdale Water Dept132234
Angle Inn Motor Court1470

Check another water system

Questions

Does Gateway Nra Sandy Hook have lead pipes?

Yes. Gateway Nra Sandy Hook reported 0 lead service lines and 45 galvanized lines that must be replaced, out of 120 total. 11 more are of unknown material.

How do I check if my home's service line is lead?

Look up your address on Gateway Nra Sandy Hook's official service line inventory, which utilities must make publicly available. You can also scratch the pipe where it enters your home: lead is soft, dull gray, scratches to shiny silver and does not attract a magnet.

When will Gateway Nra Sandy Hook replace lead service lines?

Under EPA's Lead and Copper Rule Improvements, most systems must replace lead and galvanized-requiring-replacement lines by December 31, 2037, starting from November 1, 2027. The rule is being challenged in court, so dates could change. Many utilities run free or cost-share programs now.

Has Gateway Nra Sandy Hook had lead violations?

EPA's data shows 9 Lead and Copper Rule violations since 2015, 2 health-based, 1 still open for Gateway Nra Sandy Hook.

Which water filters remove lead?

Use a filter certified to NSF/ANSI Standard 53 for lead reduction, or NSF/ANSI 58 for reverse osmosis. Check the certification on NSF's listings, not just the box.

Embed or cite this data

Local news sites, blogs and community groups can embed this card. It updates when EPA releases new data.

Citation: Lead Pipe Map, "Gateway Nra Sandy Hook lead service lines," https://leadpipemap.com/nj/gateway-nra-sandy-hook/. Source: EPA SDWIS service line inventory, 2026 Q3. Download the full dataset on the data page.