Lead Pipe Map

Hancock, NY · PWSID NY1200266

Hancock Village lead service lines

5 lead or galvanized lines to replace

Hancock Village reported 5 lead and 0 galvanized-requiring-replacement service lines out of 467 in its inventory. That's about 1 in 93 lines. Another 6 (1.3%) are still listed as unknown material.

Ranks #347 of 490 New York systems with confirmed lead lines, and #5,399 nationally.

1.1% of Hancock Village's service lines are lead or galvanized requiring replacement. That's lower than the New York average (7.6%) and lower than the national average (3.1%).

5Lead
0Galvanized, replace
6Unknown material
456Non-lead

Total service lines reported: 467. Reported all required service line types. Population served: 1,182; 483 connections.

Lead test results

Hancock Village's most recent 90th-percentile lead result (2023) was 3 ppb, below both the 15 ppb action level and the 10 ppb level that takes effect in 2027. This means 90% of homes sampled were at or below that level; individual homes, especially those with lead lines, can be higher.

1510Jul 2016–Dec 2016: 5.3 ppb20162017: 6.5 ppb20172018: 5.4 ppb20182019: 16.1 ppb2019Jan 2021–Jun 2021: not detected2021Jul 2021–Dec 2021: 1.3 ppb20212022: 1.9 ppb20222023: 3 ppb2023

Lead and Copper Rule 90th-percentile results reported to EPA, in parts per billion. Dashed lines: 15 ppb action level and the 10 ppb level from November 1, 2027.

Progress since 2025 Q1

Reported lead and galvanized-requiring-replacement lines went from 5 in 2025 Q1 to 5 in 2026 Q3: no change. Lines of unknown material went from 6 to 6, no change.

2025 Q1: 5 lead + galvanized52025 Q12025 Q2: 5 lead + galvanized52025 Q22025 Q3: 5 lead + galvanized52025 Q32025 Q4: 5 lead + galvanized52025 Q42026 Q1: 5 lead + galvanized52026 Q12026 Q2: 5 lead + galvanized52026 Q22026 Q3: 5 lead + galvanized52026 Q3

Quarterly counts reported to EPA. A drop usually means lines were replaced or confirmed non-lead; a rise usually means more lines were identified. Replacement progress rankings.

Lead rule violations

EPA's data lists 2 Lead and Copper Rule violations since 2015, 2 still open for Hancock Village. Health-based violations are treatment failures, such as corrosion control or public education; the rest are missed monitoring or reporting.

BeganViolationStatus
Oct 2025Missed follow-up or routine lead and copper tap samplingOpen
Oct 2024Missed follow-up or routine lead and copper tap samplingOpen

Source: EPA SDWIS violation records for the Lead and Copper Rule.

Where the water comes from

Hancock Village's main water source is groundwater (wells).

Source: EPA SDWIS water system and facility records.

Check your own address

These counts cover the whole system. To see whether your line is lead, use the utility's address-level inventory. Utilities had to prepare one by October 16, 2024 and make it publicly accessible; systems serving more than 50,000 people must post it online.

No map yet? Do the 2-minute scratch and magnet test on the pipe where water enters your home.

Protect your drinking water now

If your line is lead, galvanized or unknown, filter water for drinking, cooking and baby formula. Use a filter certified to NSF/ANSI 53 for lead. Run cold water for a few minutes after it sits for hours, and never use hot tap water for cooking.

How to pick a lead-certified filter · How to test your water for lead

Getting the line replaced

EPA's Lead and Copper Rule Improvements require most systems to replace lead and galvanized-requiring-replacement lines by December 31, 2037. Ask Hancock Village whether it replaces the private side for free or with a cost share before you hire anyone. If you want it done sooner, or your utility doesn't cover your side, a licensed plumber can quote it. What replacement costs.

County pages: Lead pipes in Delaware County

Other water systems nearby

SystemLead + galv.Unknown
Delhi Village20119
Sidney Village111,477
Walton Village2554
Hobart Village2413
Fleischmanns Village2200
Andes Water District3916
Treadwell Water District125
Fishs Eddy Community Water Sup67

Check another water system

Questions

Does Hancock Village have lead pipes?

Yes. Hancock Village reported 5 lead service lines and 0 galvanized lines that must be replaced, out of 467 total. 6 more are of unknown material.

How do I check if my home's service line is lead?

Look up your address on Hancock Village's official service line inventory, which utilities must make publicly available. You can also scratch the pipe where it enters your home: lead is soft, dull gray, scratches to shiny silver and does not attract a magnet.

When will Hancock Village replace lead service lines?

Under EPA's Lead and Copper Rule Improvements, most systems must replace lead and galvanized-requiring-replacement lines by December 31, 2037, starting from November 1, 2027. The rule is being challenged in court, so dates could change. Many utilities run free or cost-share programs now.

Has Hancock Village had lead violations?

EPA's data shows 2 Lead and Copper Rule violations since 2015, 2 still open for Hancock Village.

Which water filters remove lead?

Use a filter certified to NSF/ANSI Standard 53 for lead reduction, or NSF/ANSI 58 for reverse osmosis. Check the certification on NSF's listings, not just the box.

Embed or cite this data

Local news sites, blogs and community groups can embed this card. It updates when EPA releases new data.

Citation: Lead Pipe Map, "Hancock Village lead service lines," https://leadpipemap.com/ny/hancock-village/. Source: EPA SDWIS service line inventory, 2026 Q3. Download the full dataset on the data page.